6.34 Configuration 52 (Config52) Address 84
76543210
COP_THRES6 COP_THRES5 COP_THRES4 COP_THRES3 COP_THRES2 COP_THRES1 COP_THRES0 COP_INT
Number Name Description
[7:1] COP_THRES[6:0]
Value used to determine the COP Filter Threshold. The clamp is sampled
every 20s and over the selected interval is compared to COP time-on
threshold, T
ON(th)
to determine if an COP fault has occurred.
For a 1 second interval:
For a 2 second interval:
[0] COP_INT
Configures the time interval to check for a boost stage COP fault.
0 = 1 second interval
1 = 2 second interval
T
ON th
COP_THRES [6:0] 5.12ms 2.56ms+=
T
ON th
COP_THRES [6:0] 10.24ms 5.12ms+=