
CRD1611A-8W
DS1014RD3 23
9. CONDUCTED EMI
Device Under Test: CRD1611A-8W-Z Operating Conditions: NOMNIAL
Test Specification: IEC 61000-3-2 Operator Name: JDW & JCM
Scan Settings (1 Range)
Final Measurement
Detectors: QP, AV Peaks: 25 Meas Time: 1s Acc. Margin: 6dB
Final Measurement Results
Frequencies Receiver Settings
Start
Stop Step Res BW M-Time Atten Preamp
150kHz
30MHz 4.5kHz 9kHz (6dB) 10ms Auto Off
Trace
Frequency
(MHz)
Level
(dB
V)
Limit
(dBV)
Delta Limit
(dB)
Delta Ref
(dB)
Comment
1QP
0.15 62.42 66.00 -3.58 N/on
2AV
0.15 51.27 56.00 -4.73 N/on
1QP
0.546 47.18 56.00 -8.82 N/on
* = Limit Exceeded
1 MHz 10 MHz150 kHz 30 MHz
10.0
20.0
30.0
40.0
50.0
60.0
70.0
0.0
80.0
dBȝV
Limit
55022MAV
Transducer
ENV216
Traces
PK+
Comentarios a estos manuales