CS4360
DS517F2 11
ANALOG CHARACTERISTICS (CS4360-DZZ)
Test conditions (unless otherwise specified): Input test signal is a 997 Hz sine wave at 0 dBFS; measurement
bandwidth is 10 Hz to 20 kHz; test load R
L
= 10 k, C
L
= 10 pF (see Figure 2). All supplies = VA = 5.0 V and 3.3 V.
Parameter
VA = 5.0 V VA = 3.3 V
Min Typ Max Min Typ Max Unit
Single-speed Mode Fs = 48 kHz
Dynamic Range
(Note 3)
unweighted
A-Weighted
A-Weighted
89
92
-
99
102
100
-
-
-
89
92
-
94
97
97
-
-
-
dB
dB
dB
Total Harmonic Distortion + Noise
(Note 3)
0 dB
-20 dB
-60 dB
-
-
-
-91
-79
-39
-84
-
-
-
-
-
-91
-74
-34
-84
-
-
dB
dB
dB
Double-speed Mode Fs = 96 kHz
Dynamic Range
(Note 3)
unweighted
A-Weighted
40 kHz Bandwidth A-Weighted
89
92
-
99
102
100
-
-
-
89
92
-
94
97
97
-
-
-
dB
dB
dB
Total Harmonic Distortion + Noise
(Note 3)
0 dB
-20 dB
-60 dB
-
-
-
-91
-79
-39
-84
-
-
-
-
-
-91
-74
-34
-84
-
-
dB
dB
dB
Quad-speed Mode Fs = 192 kHz
Dynamic Range
(Note 3)
unweighted
A-Weighted
40 kHz Bandwidth A-Weighted
89
92
-
99
102
100
-
-
-
89
92
-
94
97
97
-
-
-
dB
dB
dB
Total Harmonic Distortion + Noise
(Note 3)
0 dB
-20 dB
-60 dB
-
-
-
-91
-79
-39
-84
-
-
-
-
-
-91
-74
-34
-84
-
-
dB
dB
dB