CRD1630-10W
DS1004RD2 23
10.CONDUCTED EMI
Device Under Test: CRD1630-10W Operating Conditions: NOMINAL at 25C
Test Specification: EN555022 Operator Name: JC
Scan Settings (1 Range)
Final Measurement
Detectors: PK+, AV Peaks: 10 Meas Time: See scan settings Acc. Margin: 3dB
Final Measurement Results
Frequencies Receiver Settings
Start Stop Step Res BW M-Time Atten Preamp
150kHz 30MHz 4.5kHz 9kHz (6dB) 10ms Auto Off
Trace
Frequency
(MHz)
Level
(dB
V)
Limit
(dBV)
Delta Limit
(dB)
Delta Ref
(dB)
Comment
1 PK+ 2.427 53.34 56.00 -2.66 L1 / on
* = Limit Exceeded