Cirrus-logic CS2000-CP Manual de usuario Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 38
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
CS2000-CP
DS761F2 11
CONTROL PORT SWITCHING CHARACTERISTICS - SPI FORMAT
Inputs: Logic 0 = GND; Logic 1 = VD; C
L
=20pF.
Notes: 13.
t
spi
is only needed before first falling edge of CS after power is applied. t
spi
= 0 at all other times.
14. Data must be held for sufficient time to bridge the transition time of CCLK.
15. For f
cclk
< 1 MHz.
Parameter Symbol Min Max Unit
CCLK Clock Frequency f
ccllk
-6MHz
CCLK Edge to CS
Falling (Note 13)t
spi
500 - ns
CS
High Time Between Transmissions t
csh
1.0 - µs
CS
Falling to CCLK Edge t
css
20 - ns
CCLK Low Time t
scl
66 - ns
CCLK High Time t
sch
66 - ns
CDIN to CCLK Rising Setup Time t
dsu
40 - ns
CCLK Rising to DATA Hold Time (Note 14)t
dh
15 - ns
Rise Time of CCLK and CDIN (Note 15)t
r2
- 100 ns
Fall Time of CCLK and CDIN (Note 15)t
f2
- 100 ns
Delay from Supply Voltage Stable to Control Port Ready t
dpor
100 - µs
t
r2
t
f2
t
dsu
t
dh
t
sch
t
scl
CS
CCLK
CDIN
t
css
t
csh
t
spi
t
dpor
VD
Figure 6. Control Port Timing - SPI Format (Write Only)
Vista de pagina 10