2. CHARACTERISTICS AND SPECIFICATIONS
RECOMMENDED OPERATING CONDITIONS
AGND = 0 V; all voltages with respect to ground.
ABSOLUTE MAXIMUM RATINGS
AGND = 0 V; all voltages with respect to ground.
WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation
is not guaranteed at these extremes.
Parameters Symbol Min Nom Max Units
DC Power Supply
VA
VL
4.75
1.7
5.0
3.3
5.25
5.25
V
V
Specified Temperature Range Commercial T
A
-40 - +85 C
Parameters Symbol Min Max Units
DC Power Supply
VA
VL
-0.3
-0.3
6.0
VA
V
V
Input Current, Any Pin Except Supplies I
in
10mA
Digital Input Voltage (pin 8, RST
)V
IND
-0.3 VA+0.4 V
Digital Input Voltage (all other digital pins) V
IND
-0.3 VL+0.4 V
Ambient Operating Temperature (power applied) T
op
-55 125 °C
Storage Temperature T
stg
-65 150 °C