2.8.3 Setup and Test Window
The Setup and Test window allows the user a way to access CS5484 registers and send commands to
the CS5484 directly (see Figure 31).
Figure 31. Setup and Test Window
There are three types of transactions: Write, Read, and Send. The CS5484 memory is organized by pag-
es. In order to properly write a register it is necessary to set the Page, Address, and Value to Write field
and then press the Write button. To read a register it is necessary to set the Page and Address and then
press the Read button. The register result will be displayed in the Value Read field. To send a command
to the CS5484, enter the command in the Command field and press the SEND button. Refer to the
CS5484 data sheet for more details on registers and commands.