9. CONDUCTED EMI
Device Under Test: CRD1615-8W-Z Operating Conditions: NOMINAL
Test Specification: EN55022:2010 Operator Name: CAL
Scan Settings (1 Range)
Final Measurement
Detectors: QP, AV Peaks: 10 Meas Time: See scan settings Acc. Margin: 12dB
Final Measurement Results
Frequencies Receiver Settings
Start Stop Step Res BW M-Time Atten Preamp
150kHz 30MHz 4.5kHz 9kHz (6dB) 50ms Auto Off
Trace
Frequency
(MHz)
Level
(dB
V)
Limit
(dBV)
Delta Limit
(dB)
Delta Ref
(dB)
Comment
1QP 0.15 58.05 66.00 -7.95 N/on
2AV 10.0005 41.04 50.00 -8.96 N/on
* = Limit Exceeded