7. INDUCTOR CONSTRUCTION
The CRD1616-8W provides power factor correction and dimmer compatibility with a constant output current, quasi-
resonant flyback stage. The following sections describe the flyback transformer installed on the CRD1616-8W.
7.1 Flyback Transformer
The flyback transformer stage is a quasi-resonant peak current-regulated DC-DC converter capable of delivering
the highest possible efficiency with constant current output while minimizing line frequency ripple. The auxiliary wind-
ing is used for zero-current detection and overvoltage protection.
7.1.1 Electrical Specifications
Characteristics conditions:
• Operating temperature range: -25 °C to +120 °C (including coil heat)
Notes: 1. Time = 2sec.
2. Measured across pins 4 and 5.
3. Measured across pins B and A.
4. Measured across pins 6 and 7.
Parameter Condition Sym Min Typ Max Unit
Flyback Transformer
Electrical Strength (Note 1)
f
operate
=50/60Hz
- 1200 - V
RMS
Primary Inductance (Note 2)
f
resonant
=10kHz, 0.3V at
20°C
L
P
3.6 4.0 4.4 mH
Primary Leakage Inductance (Note 2)
f
resonant
=10kHz, 0.3V at
20°C
L
K
--80H
Primary DC Resistance (Note 2)
t
DCR
=20°C
8.8 11 13.2
Secondary DC Resistance (Note 3)
t
DCR
=20°C
- - 0.372
Auxiliary DC Resistance (Note 4)
t
DCR
=20°C
0.304 0.38 0.456
99.5T
#37AWG
(0.12mm)
140.5 T
#37 AWG
(0.12 mm)
25T
#31AWG
(0.226mm)
Primary
4
8
5
6
Auxiliary
7
Secondary
32T
#30AWG
(0.25mm)
A
B
Figure 10. Flyback Transformer Schematic