CRD1616-8W
22 DS1003RD4
9. CONDUCTED EMI
Device Under Test: CRD1616-8W-Z Operating Conditions: NOMINAL
Test Specification: EN55022:2010 Operator Name: CAL
Scan Settings (1 Range)
Final Measurement
Detectors: QP, AV Peaks: 25 Meas Time: See scan settings Acc. Margin: 12dB
Final Measurement Results
Frequencies Receiver Settings
Start Stop Step Res BW M-Time Atten Preamp
150kHz 30MHz 4.5kHz 9kHz (6dB) 50ms Auto Off
Trace
Frequency
(MHz)
Level
(dB
V)
Limit
(dBV)
Delta Limit
(dB)
Delta Ref
(dB)
Comment
1 QP 0.15 58.20 66.00 -7.80 N / on
2 AV 0.1815 42.87 54.42 -11.55 N / on
1 QP 2.5125 52.99 56.00 -3.01 N / on
2 AV 10.0005 40.93 50.00 -9.07 N / on
* = Limit Exceeded
Figure 23. Conducted EMI