Cirrus-logic CS4397 Manual de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
CS4397
DS333F1 13
SWITCHING CHARACTERISTICS - CONTROL PORT
(T
A
= 25 °C; VD = 5.25 V to 3.0 Volts; Inputs: logic 0 = AGND, logic 1 = VD, C
L
= 30 pF)
Notes: 11. Data must be held for sufficient time to bridge the 300 ns transition time of SCL.
Parameter Symbol Min Max Unit
I
2
C
®
Mode
SCL Clock Frequency f
scl
- 100 KHz
RST
Rising Edge to Start t
irs
500 - ns
Bus Free Time Between Transmissions t
buf
4.7 - µs
Start Condition Hold Time (prior to first clock pulse) t
hdst
4.0 - µs
Clock Low time t
low
4.7 - µs
Clock High Time t
high
4.0 - µs
Setup Time for Repeated Start Condition t
sust
4.7 - µs
SDA Hold Time from SCL Falling (Note 11) t
hdd
0-µs
SDA Setup time to SCL Rising t
sud
250 - ns
Rise Time of Both SDA and SCL Lines t
r
-1µs
Fall Time of Both SDA and SCL Lines t
f
- 300 ns
Setup Time for Stop Condition t
susp
4.7 - µs
t
buf
t
hdst
t
hdst
t
low
t
r
t
f
t
hdd
t
high
t
sud
t
sust
t
susp
Stop Start
Start
Stop
Repeated
SDA
SCL
t
irs
RST
Figure 4. I
2
C Control Port Timing
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 33 34