DS785UM1 5-29
Copyright 2007 Cirrus Logic
System Controller
EP93xx User’s Guide
5
5
SWRST: Software reset. A one to zero transition of this bit initiates
a software reset.
VidClkDiv
Address:
0x8093_0084 - Read/Write, Software locked
Default:
0x0000_0000
Definition:
Configures video clock for the raster engine. Selects input to VCLK dividers
from either PLL1 or PLL2, and defines a programmable divide value.
Bit Descriptions:
RSVD: Reserved. Unknown During Read.
VENA: Enable VCLK divider.
ESEL: External clock source select.
0 - use the external XTALI clock input as the clock source.
1 - use one of the internal PLLs selected by PSEL as the
clock source.
PSEL: PLL source select.
1 - select PLL2 as the clock source.
0 - select PLL1 as the clock source.
PDIV: Pre-divider value. Generates divide by 2, 2.5, or 3 from the
clock source.
00 - Disable clock
01 - Divide-by-2
10 - Divide-by-2.5
11 - Divide-by-3
VDIV: VCLK divider value. Forms a divide-by-N of the pre-divide
clock output. VCLK is the source clock divided by PDIV
divided by N. Must be at least two.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
1514131211109876543210
VENA ESEL PSEL RSVD PDIV RSVD VDIV