CRD5376
DS612RD2 5
1. INITIAL SETUP
1.1 Kit Contents
The CRD5376 reference design kit includes:
CRD5376 reference design board
USB cable (A to mini-B)
Software download information card
The following are required to operate CRD5376, and are not included:
Bipolar power supply with clip lead outputs (± 3.3 V, 300 mA)
PC running Windows XP
®
or Windows 2000™ with an available USB port
Internet access to download the evaluation software
1.2 Hardware Setup
To set up the CRD5376 reference design hardware:
Verify all jumpers are in the default settings (see next section).
With power off, connect the CRD5376 power inputs to the power supply outputs.
J8 pin 17 = -3.3 V
J8 pin 18 = 0 V
J8 pin 19 = +3.3 V
J8 pin 20 = 0 V
Connect the USB cable between the CRD5376 USB connector and the PC USB port.
Proceed to the Software Setup section to install the evaluation software and USB driver.